Infrastructure & Specs

What we engineer into every facility we design and build.

AIR · CRAHREAR-DOOR HXDIRECT-TO-CHIP LIQUID0 kW20 kW50 kW100 kW140 kW160 kWCPU rackHGX B300 (air)GB300 NVL72Vera Rubin NVL144Per-rack IT loadWe engineer to 140 kW/rack · 1,600 kg loaded
Rack density decides the cooling regime. Above ~50 kW there is no air-cooled option.
Specifications

Reference Specifications

Compute generationsNVIDIA GB300 NVL72, HGX B300, Vera Rubin NVL144-ready; AMD Instinct MI355X
Rack density designsUp to 140 kW per rack, direct-to-chip liquid + rear-door HX; 1,600 kg loaded rack structural
Power systems415 V 3-phase and OCP power shelves; 800 VDC-ready busway; N+1 to 2N UPS; behind-the-meter generation
Cooling systemsRow/facility CDUs, warm-water (W32/W45) free cooling, heat reuse; PUE 1.1 design target
Network fabricsQuantum-X800 InfiniBand, Spectrum-X / Arista 800G Ethernet, rail-optimised; 1.6T-ready optics
StorageVAST / WEKA / DDN parallel file, GPUDirect Storage, NVMe media
Cluster softwareKubernetes, Slurm, NVIDIA Mission Control, DCIM integration
Compliance-ready designsSOC 2, ISO 27001, HIPAA; FedRAMP path for government facilities
Physical security designManned posts, biometric access, mantraps, per-cage CCTV
ResilienceConcurrently maintainable (Tier III+) designs, uptime-SLA-ready
Headquarters12800 Westridge Blvd STE 109, Frisco, TX 75035
Deployment tiers

Three Reference Designs

Each tier is a complete bill of materials, floor plan and commissioning plan — scaled from a pilot row to a full SuperPOD.

SMALL · 1–8 RACKS · TO 200 KWRear-door HX · airUPSEthernet fabric · rack PDUs · weeks

Small

1–8 racks · to 200 kW

Air-cooled or rear-door HX GPU rows for enterprise pilots and inference. Ethernet fabric, rack PDUs, single UPS module. Deployed in weeks.

Request pricing
MEDIUM · 8–64 RACKS · 0.5–3 MWROW CDU · BUSWAYDTC liquid · N+1 · IB / Spectrum-X

Medium

8–64 racks · 0.5–3 MW

Direct-to-chip liquid cooling with row CDUs, overhead busway, N+1 power. NVL72-class racks, InfiniBand or Spectrum-X fabric, parallel storage.

Request pricing
LARGE · SUPERPOD · 10 MW+PLANTMV SWITCHGEAR · 800 VDCFull EPC · L1–L5 commissioning

Large

SuperPOD · 10 MW+

Facility-scale water plant, MV switchgear and dedicated substation, 800 VDC-ready distribution, exascale storage. Full EPC delivery and L1–L5 commissioning.

Request pricing

Ready to scope your build?

Talk to our engineering team. Every inquiry gets a same-day response and a dedicated solutions engineer.

Start a conversation